| MODEL | PrOffice-350
|
PrOffice-550
|
PrOffice-650
|
||
| CAPACITY | VA/W | 350VA/210W
|
550 VA / 330W
|
650VA / 390W
|
|
| INPUT | Phase | Single
|
|||
| Voltage | 120 VAC or 220/230/240VAC |
||||
| Voltage Range | 99~141 VAC/182~258/190~270/198~282 VAC
|
||||
| Frequency | 50/60Hz |
||||
| Frequency Range | 45~55Hz/55~65Hz |
||||
| OUTPUT (Inverter Mode) |
Phase | Single
|
|||
| Voltage | 120 VAC or 230 VAC |
||||
| Voltage Regulation (Batt. Mode) |
+/- 10% |
||||
| Frequency | 50Hz
or 60 Hz
|
||||
| Frequency Redulation(Batt. Mode) |
+/- 1Hz |
||||
| Output Waveform(Batt. Mode) | Modified
Sinewave
|
||||
| POWER FACTOR | P.F. | 0.6 |
0.6 |
0.6 |
|
| TRANSFER TIME | Typical | 2~6ms |
|||
| BATTERY | Battery Type & Number | 12V4.5Ah x 1pc
|
12V7Ah
x 1pc
|
||
| Recharging Time | 24
hours up to 90% after complete discharge
|
||||
| Backup Time (at a PC load with 15" monitor) | 8 minutes |
20 minutes |
|||
| Backup Time (at a PC load with 17" monitor) | 6 minutes
|
16
minutes
|
|||
| INDICATOR | AC Mode | Green LED lighting
|
|||
| Battery Mode | Orange LED flashing every 10 seconds |
||||
| Low Battery at Battery
Mode |
Red LED Lighting |
||||
| Fault | Red LED Lighting |
||||
| Battery Weak at AC Mode | Red LED Lighting |
||||
| Battery Fault at AC Mode | Red LED Lighting |
||||
| Overload | N / A |
||||
| AUIBLE ALARM | Battery Mode | Sounding
Every 10 Seconds
|
|||
| Low Battery at Battery Mode | Sounding
Every Second
|
||||
| Battery Replacement | Sounding
every 2 seconds
|
||||
| Fault | Continuously
Sounding
|
||||
| PROTECTION | Full Protection | Deep
Discharge, Overcharge, Short Circuit Protection
RJ 11 Modem/Telephone Protection x 3 |
|||
| PHYSICAL | Dimension (DxWxH) | 297X192X90
(mm)
|
|||
| Net Weight | 4.5kgs
|
6kgs
|
6.4kgs
|
||
| Outlets | |||||
| NEMA type | 6 outlets (2 for surge protection, 4 for backup)
|
||||
| Shuko type | 4
outlets (1 for surge protection, 3 for backup)
|
||||
| French type | 4
outlets (1 for surge protection, 3 for backup)
|
||||
| Australian type | 5
outlets (2 for surge protection, 3 for backup)
|
||||
| BS1363 type | 4
BS1363 +1 IEC outlets
(1 BS1363 for surge protection, 4 for back up) |
||||
| ENVIRONMENT | Operation Environment | 0~40 Degrees Centigrade, 20~90% Relative humidity(non-condensing)
|
|||
| Noise Level | Less than 40dB
|
||||
| INTERFACE | Smart RS-232 | Windows
95/98/NT/2000/ME/XP, Novell, and Linux
|
|||
| USB Port Option | Optional
|
||||
* We will use equivalent type of batteries when mentioned batteries are in shortage.
** Product specifications are subject to change without further notice.