| MODEL | Blazer
Vista 400
|
Blazer
Vista 600
|
Blazer
Vista 800
|
|
| CAPACITY | VA/W | 400VA/240W
|
600VA/360W
|
800VA/480W
|
| INPUT | Phase | Single
|
||
| Voltage | 110/120VAC or 220/230/240VAC |
|||
| Voltage Range | 81-145VAC
/ 162-290VAC +/- 5%
|
|||
| Frequency |
50Hz / 60Hz ( Auto Sensing)
|
|||
| Frequency Range | 45~55 Hz / 55~65Hz
|
|||
| OUTPUT | Phase | Single
|
||
| Voltage(Btt. Mode) | 110/120VAC or 220/230/240VAC |
|||
| Voltage Regulation(Batt. Mode) |
±10%
|
|||
| Frequency |
50Hz or 60Hz
|
|||
| Frequency Regulation (Batt. Mode) |
+/-1 Hz
|
|||
| Output Waveform |
Modified Sinewave
|
|||
| Power Factor | P.F. | 0.6 |
0.6 |
0.6 |
| BATTERY | Battery Type & Number | 12V/4.5AH x 1pcs
|
12V/28W x 1pc
|
12V/34W x 1pc
|
| Back up Time (at a PC load with 15"monitor) | 10 minutes
|
20 minutes
|
29 minutes
|
|
| Recharge Time |
8 hours to 90% after
complete discharge
|
|||
| TRANSFER TIME | Typical |
2-6ms
|
||
| INDICATOR | LCD Indicator with Blue Back Light |
The LCD will self turn on when the UPS is
functioning including in, off, charging mode and fault mode
|
||
| AUDIBLE ALARM | Battery Mode |
Sounding every 10
seconds
|
||
| Low Battery | Sounding
every second
|
|||
| Overload |
Sounding every 0.5
second
|
|||
| Battery Replacement |
Sounding every 2
seconds
|
|||
| Fault |
Continously sounding
|
|||
| PROTECTION | Full Protection |
Discharge, overcharge,
and overload protection
|
||
| PHYSICAL | Dimension, DXWXH (mm) |
330X100X140
|
||
| Net Weight (kgs) | 5
|
6
|
6.5
|
|
| ENVIRONMENT | Operating Environment |
0~40 Degrees Centigrade, 0~90%
relative humidity (non-condensing)
|
||
| Noise Level |
Less than 40dB
|
|||
| INTERFACE | Smart RS-232 |
Support Windows family, Linux, IBM Aix, Sun Solaris, Compaq True64, UnixWare,
FreeBSD,
HP-UX, and MAC
|
||
| USB Option | N / A |
|||
* We will use equivalent type of batteries when mentioned batteries are in shortage.
**Product specifications are subject to change without further notice